Interaction Details


Details of experiments between Q8N448 and Q9UPQ7
Note that the results of all experiments are listed, regardless of the modification states of the fragments.



Experiment series 1

Protein A

Protein: LNX2
Fragment: 334-426
Site: PDZ_2
Construct: his6-MBP-TEVsite-PDZ

Protein B

Protein: PDZRN3
Fragment: 1057-1066
Site: PBM
Sequence: YNSFLSVTTV
Construct: Biotin-Ahx-YNSFLSVTTV
Average holdup BI: 0.58
Normalized holdup BI: 0.58
Immobilized partner concentration (10-6M): 18
Experiment method: DAPF_holdup
Details of affinity fitting: fluorescein + mCherry internal standards + normalization based on CALIP_holdup data + reverse layout
Number of measurements: 1
Measured pKd: 4.94
PUBMED ID: 36115835
Experimental Details

The peptide stock solution had solubility issues. The peptide concentration in the affinity conversion step may differ from reality causing a systematic error in reported affinities.


Experiment series 2

Protein A

Protein: LNX2
Fragment: 681-690
Site: PBM
Sequence: TVICWPGSLV
Construct: Biotin-Ahx-TVICWPGSLV

Protein B

Protein: PDZRN3
Fragment: 245-339
Site: PDZ_1
Construct: his6-MBP-TEVsite-PDZ
Average holdup BI: 0.16
Normalized holdup BI: 0.2
Immobilized partner concentration (10-6M): 18
Experiment method: DAPF_holdup
Details of affinity fitting: fluorescein + mCherry internal standards + normalization based on CALIP_holdup data + reverse layout
Number of measurements: 1
Measured pKd: 4.17
PUBMED ID: 36115835
Experimental Details

The peptide stock solution had solubility issues. The peptide concentration in the affinity conversion step may differ from reality causing a systematic error in reported affinities.


Experiment series 3

Protein A

Protein: LNX2
Fragment: 459-560
Site: PDZ_3
Construct: his6-MBP-TEVsite-PDZ

Protein B

Protein: PDZRN3
Fragment: 1057-1066
Site: PBM
Sequence: YNSFLSVTTV
Construct: Biotin-Ahx-YNSFLSVTTV
Average holdup BI: 0.03
Normalized holdup BI: 0.03
Immobilized partner concentration (10-6M): 18
Experiment method: DAPF_holdup
Details of affinity fitting: fluorescein + mCherry internal standards + normalization based on CALIP_holdup data + reverse layout
Number of measurements: 1
The affinity was below the detection threshold of the assay.
PUBMED ID: 36115835
Experimental Details

The peptide stock solution had solubility issues. The peptide concentration in the affinity conversion step may differ from reality causing a systematic error in reported affinities.